Here is a full list of advanced settings (parameters) for ZEN21 On/Off SwitchVER. 4.01 firmware:
This is product is discontinued and replaced with ZEN71.
What does that mean?
On/Off Paddle Orientation
Parameter 1:Choose if you want the upper paddle to turn the light on or turn the light offwhen tapped.
Values:0 – Upper paddle turns the light on,lower paddle turns it off (default); 1 – Upperpaddle turns the light off, lower paddle turns iton; 2 – Any paddle turns light on/off.
Size:1 byte dec
LED Indicator Control
Parameter 2:Choose if you want the LEDindicator to turn on when the switch (light) ison or off, or if you want it to remain on or off atall times.
Values:0 – LED indicator is on when switch isoff, LED indicator is off when switch is on(default); 1 – LED indicator is on when switch ison, LED indicator is off when switch is off; 2 –LED indicator is always OFF; 3 – LED indicatoris always ON.NOTE:tap the upper paddle 6 times quickly to change this mode.
Size:1 byte dec
Auto Turn-Off Timer
Parameter 3:Use this parameter to enable ordisable the auto turn-off timer function.
Values:0 – timer disabled (default); 1 – timerenabled.
Size:1 byte dec
Parameter 4:Use this parameter to set thetime after which you want the switch toautomatically turn off once it has been turnedon. The number entered as value correspondsto the number of minutes.
Values:1 – 65535 (minutes). Default: 60.
Size:4 byte dec
Auto Turn-On Timer
Parameter 5:Use this parameter to enable ordisable the auto turn-on timer function.
Values:0 – timer disabled (default); 1 – timerenabled.
Size:1 byte dec
Parameter 6:Use this parameter to set thetime after which you want the switch toautomatically turn on once it has been turnedoff. The number entered as value correspondsto the number of minutes.
Values:1 – 65535 (minutes). Default: 60.
Size:4 byte dec
Association Reports
Parameter 7:Choose which physical and Z-Wave triggers should prompt the switch to send a status change report to associated devices.
Values:0 – none; 1 – physical tap on ZEN21only; 2– physical tap on connected 3-way switch only; 3– physical tap on ZEN21or connected 3-way switch;4– Z-Wave command from hub;5– physical tap on ZEN21or Z-Wave command from hub;6– physical tap on connected 3-way switch or Z-Wave command from hub;7– physical tap on ZEN21/connected 3-way switch or Z-Wave command from hub;8 – timer only;9 – physical tap on ZEN21or timer;10 – physical tap on connected 3-way switch or timer;11 – physical tap on ZEN21/connected 3-way switch or timer; 12 – Z-Wave command from hub or timer;13 – physical tap on ZEN21, Z-Wave command from hub, or timer;14 – physical tap on ZEN21/ connected 3-way switch, Z-Wave command from hub, or timer;12 – all of the above. Default: 15.
Size:1 byte dec
On Off Status After Power Failure
Parameter 8:Set the on off status for theswitch after power failure.
Values:0 – forced to OFF (regardless of stateprior to power outage); 1 – forced to ON(regardless of state prior to power outage); 2 –remembers and restores on/off status afterpower failure (default)
Size:1 byte dec
Enable/Disable Scene Control
Parameter 9:Enable or disable scene controlfunctionality for quick double tap triggers.
Values:0 – scene control disabled (default). 1 –scene control enabled.
Size:1 byte dec
Smart Bulb Mode: Enable/Disable Paddle / Z-Wave Control
Parameter 11:Enable or disable local on/offcontrol. If enabled, you’ll only be able tocontrol the connected light via Z-Wave. Scenesand other functionality will still be availablethrough paddles.
Values:0 – physical paddle control disabled. 1 – physical paddle control enabled (default). 2 – physical paddle and Z-Wavecontrol disabled.NOTE:tap the upper paddle 10 times quickly to change this mode.
Size:1 byte dec
Parameter 13:Set reporting behavior for disabled physical control.
Values:0 – switch reports on/off status and change LED indicator state even if physical and Z-Wave control is disabled (default). 1 – switch doesn't report on/off status or change LED indicator state when physical (and Z-Wave) control is disabled.
Size:1 byte dec
3-Way Switch Type
Parameter 12:Choose the type of 3-way switch you want to use with this switch in a 3-way set-up.
Values:0 – regular mechanical 3-way on/off switch, use the connected 3-way switch to turn the light on or off (default); 1 – momentary switch, click once to change status (light on or off)
Size:1 byte dec
MANUAL CONTROL
Upper Paddle:
1 x tap: load on; Scene 2, attribute 00 (button 1)
2 x tap: Scene 2, attribute 03 (button 3)
3 x tap: enter inclusion (pairing)mode; Scene 2, attribute 04(button 5)
4 x tap:Scene 2, attribute 05(button 7)
5 x tap:Scene 2, attribute 06(button 9)
6 x tap: change LED indicator mode (see parameter 2)
tap-tap-tap-tap-and-hold: change physical / Z-Wave control mode (see parameter 11)
held:Scene 2, attribute 01
released:Scene 2, attribute 02
tap-tap-tap-and-hold: factory reset
Lower Paddle:
1 x tap: load off; Scene 1, attribute 00 (button 2)
2 x tap: Scene 1, attribute 03 (button 4)
3 x tap: enter exclusion (unpairing)mode; Scene 1, attribute 04(button 6)
4 x tap:Scene 1, attribute 05(button 8)
5 x tap:Scene 1, attribute 06(button 10)
held:Scene 1, attribute 01
released:Scene 1, attribute 02
tap-tap-tap-and-hold: factory reset
How to Access Advanced Settings:
SmartThings
Hubitat
Vera
Home Assistant
All ZEN21 VER. 3.0 and 4.0 switches can be updatedvia OTA firmware updates, here is how to do that.You canaccess all firmware files hereafter youregister your productandcreate an account here. Questions? Justreach outto our tech support team, we're here 7 days a week!